Axium AX-400DA Multi-Zone Digital Amplifier Instruction Manual
Typical System Configuration Zone 1 Gym AX-KPD Zone 2 Study AX-KPC Zone 4 Lounge TABLE
11Typical System Configuration – Continued FIG 1 depicts a typical configuration where the 400DA amplifier is providing audio into three of the poss
Multiple Amplifier Stacks To Next AX-400DA or AX-800DAV Multi-Zone Amplifier CD PLAYER SATELLITE RECEIVER TUNER DVD PLAYER FIG 2 In larg
Controller Termination The 400DA is packed with control options: • USB: Intended for initial installation Programming or firmware update. Not int
WEB Application The Axium 400DA amplifier has a WEB application which may be used for control and monitoring of amplifier and source functions.
Zone Control Page The Zone Control Page provides status & control of: • Standby • Volume: Slider or Up/Down button with readout. • Source Sele
Zone Settings Page The Zone Settings Page provides status & control of: • Bass: Slider or Up/Down button • Treble: Slider or Up/Down button
Axium Music Centre Program AMC is an amplifier setup program, full control and tracking of the Axium amplifier zone is provided. The program runs on
The Setup button opens the Setup window. Provides adjustments for Zone Equalisation, Balance, Delay, and Zone linking assignment. The Analog source
RS232 Protocol The RS232 serial port provides data acquisition and control of the Axium amplifiers by a home automation system, or PC. The intercon
Important Safety Instructions 1 Read these instructions. 15 Unplug this apparatus during lightning storms or when unused for long periods of time.
Data Command Content Standby (01) 00 – Standby OFF 01 – Standby ON 04 – Toggle Mute (02) 00 – Mute 01 – Un-mute 02 – Toggle Mute Source Sel
Command Content Preset Selection (1E) All Zone function: Zone byte = FF 00 – Default : exit preset mode 01 – Force “Page Preset” 02 – Select Preset
22Specifications Amplifier Section Rated Output Power (FTC) All Channels: 50 Watts /channel, 8 loads THD (Total Harmonic Distortion)
Precautions 1. AC Fuse - The AC fuse inside the unit is not user-serviceable. If you cannot turn on the unit, contact the dealer from whom you purch
DECLARATION OF CONFORMITY We declare under our sole responsibility that this product, to which this declaration relates, is in conformity with the f
Supplied Accessories Table of Contents Important Safety Instructions 2 Make sure you have the following accessories: Precautions 3 Dec
Features Thank you for purchasing an Axium AX-400DA Multi-Zone Amplifier. Please read this manual thoroughly before making connections and plugging in
Presets and Paging There are 14 amplifier presets and two page presets. Presets 1 - 14 are momentary and cause the amplifier to go to a predetermine
Front Panel Guide 1 2
Rear Panel Guide 1 2 3 4 5 6 7 8